Bonded anchor point for bitumen roofs

Our anchor point is torch-bonded to the existing bituminous roof covering, without penetrating the roof covering. Order directly online from €69 each excl. VAT.

Two red anchor points, bonded with a cover strip on a flat bitumen roof

Suitable for your bitumen roof?

The connection to the bituminous roof covering is load-bearing. That is why our anchor point sets minimum requirements for the roof covering and its condition.

  • The roof covering meets the minimum values for tensile strength, tear strength and shear force
  • No cracks, blisters or loose layers at the mounting position
  • The roof covering is demonstrably connected to the insulation and roof deck
  • Roof covering older than 15 years: an on-site adhesion test is mandatory before installation
All limitations per roof type

Minimum requirements bitumen

  • Tensile strength≥ 300 N/50mm
  • Tear strength≥ 150 N/50mm
  • Shear strength≥ 500 N/50mm
  • Peel strength≥ 125 N/50mm

Torch-bonded in four steps

Our anchor point is fully bonded to the bituminous roof covering. Because the underside of the plate is not visible after placement, the installation method must be followed consistently.

  1. 01

    Heat the substrate carefully

  2. 02

    Apply and roll the second bitumen membrane

  3. 03

    Press the plate down fully and evenly

  4. 04

    Check adhesion thoroughly

Price per anchor point

Prices per unit, excl. VAT. In bundles the price per unit drops.

1+ units

€119

per unit

Order

5+ units

€99

per unit

Order

25+ units

€79

per unit

Order
Most ordered

100+ units

€69

per unit

Order

Frequently asked questions about bitumen